Robin Moffatt 8/4/2011

ODI 10g connectivity problem with OCI

Read Original

The article details a specific Oracle Data Integrator (ODI) 10g connectivity problem when using OCI to connect to an Oracle 11g database. It describes a timeout error, rules out common TNS configuration issues, and identifies the root cause as using an incompatible version of the ojdbc5.jar driver. The solution involves using the correct driver version (for 11.1.0.6) instead of a newer one.